The measurement

Two glints and a pupil

Near-infrared light from each end of the bar reflects off the cornea as two bright points, the glints. The camera records them and the dark pupil in the same frame. As the eye turns, the pupil moves and the glints barely do.

NIR LED camera NIR LED

Light in, glints out

A group of three LEDs at each end of the sensor bar shines near-infrared light up toward the eye. Each group reflects off the smooth front of the cornea as one bright point, a glint, sitting just below the pupil because the light comes from below. The camera at the centre records both glints and the dark pupil in a single frame.

glint glint pupil centre

What the detector finds

From that frame the detector makes sub-pixel position estimates of three things: the two corneal glints and the centre of the pupil.

Looking ahead Looking right The glints barely move; the pupil shifts with gaze direction.

From points to gaze: PCCR

The vector between the glints and the pupil centre is the pupil-centre corneal-reflection (PCCR) measurement. As the eye rotates the pupil moves while the glints barely move, so the vector changes predictably with gaze direction.